Panbu Electric

Solutions

From parameter matching to whole-line energy optimization, we provide an all-in-one retrofit solution integrating motors, drives, and controls.

Solution Categories
Industries

Current filters:Industry: Rubber Tires + Category: Motor, total3Bundle Options (Select Multiple)

Motor replacement solutions

Motor · Industrial Motor Replacement

Motor replacement solutions

Address challenges such as aging equipment, motor maintenance needs, and high procurement costs. Leveraging motor parameters, mechanical dimensions, and actual operating conditions, we provide 1 compatible industrial motor replacement solutions for 1, requiring no structural modifications to your equipment.

Use Cases

Motor replacement for aging equipment, domestic substitution for imported motors, and replacement of discontinued models

Solve pain points

Original model discontinued; procurement is difficult.High maintenance costs and frequent failuresComplex installation size matching

Solution Composition

Parameter mapping and selection matching / Mechanical dimension 1 to 1 compatibility / On-site replacement and commissioning support

Industrial Energy Saving Solutions Consultation

Motor · Energy Consulting

Industrial Energy Saving Solutions Consultation

Factory-wide motor system energy-saving diagnostics and retrofit planning, delivering phased implementation roadmaps and ROI projections.

Use Cases

Comprehensive audit of factory-wide motor systems, energy-saving project assessment, and carbon management planning

Solve pain points

Missing factory-wide energy consumption dataDifficulty deciding on modernization prioritiesProject initiation lacks calculation basis

Solution Composition

Factory-wide motor survey / Energy-saving ROI calculation / Phased retrofit planning

Energy-saving retrofit of switched reluctance motor speed control system

Motor · SRM Drive Retrofit

Energy-saving retrofit of switched reluctance motor speed control system

Replace the existing asynchronous motor + VFD/electromagnetic drive system with the Panpu SRM series Switched Reluctance Motor Drive (SRD). Designed for underloaded ("big horse pulling small cart") and heavy-load frequent start-stop conditions, it matches motor output to actual load requirements. Overall efficiency exceeds that of AC asynchronous motor VFD systems by more than 3%, and in low-speed conditions, by over 10%. Typical energy savings range from 10% to 50%.

Use Cases

Oilfield pumping units and well testing machines, injection molding machines and extruders, horizontal boring mills and vertical lathes, screw presses and brick pressing machines, ball mills and crushers, fans and pumps with compressors, etc., under variable load conditions, heavy-load starting, frequent forward/reverse rotation, and frequent start/stop operations.

Solve pain points

The motor's rated power far exceeds the equipment's actual operating power, resulting in low efficiency during prolonged light-load operation.High starting torque is required for overloaded or high-inertia equipment; standard induction motors draw 0 to 7 times the rated current, causing grid surges.Motor overheats significantly during low-speed VFD operation; temperature rise compromises insulation life.Frequent load fluctuations and rapid forward/reverse cycling cause accelerated wear and high failure rates in transmission and electrical components.No-load power factor is only 0.2~0.4; additional reactive power compensation equipment is required.Device status is not visible; lack of power consumption and operational data hinders energy-saving decisions.

Solution Composition

Load profile mapping and power matching for selection (0.55~315kW, 750/1000/1500/3000r/min four rated speed options) / Panpu SRM Switched Reluctance Motor (rotor without windings or permanent magnets, H-class insulation, IP54 protection rating) / SRD Intelligent Controller (dual-loop speed and current control, wall-mounted, IP23 protection rating) / Mechanical interface and mounting dimension compatibility (132~355 frame sizes, 1x1 to replace existing mounting locations) / Protection and self-diagnostic configuration (overvoltage, undervoltage, phase loss, overload, stall, overcurrent, output short circuit, overheating) / Digital motor IoT platform integration (real-time monitoring of energy consumption, production capacity, and operating conditions) / On-site installation, commissioning, and operational data acceptance

4Step-by-step service process

01

On-site survey

Collect load conditions, installation dimensions, and operating data

02

Selection Match

1 matches 1 parameter; output substitution and supporting solutions

03

Implementation

Replace in batches during maintenance windows to reduce downtime.

04

Energy Saving Verification

Before and after data comparison, generate verification report

Looking for a motor and energy-saving solution tailored to your operating conditions?

Submit request. Our technical engineer will contact you within 1 business days.