Wolong High-Voltage VFD Case Study | Middle East AL-WAHA Oilfield Project | 3700kW Injection Pump Variable Frequency Drive
Project: Middle East AL-WAHA Oilfield Phase II HVC Location: Middle East Commissioning Date: 2012 Year 7 Month Equipment Configuration: 3700 kW × 1 Units Load Type: Injection Water Pumps The same platform products were also used for the AL-WAHA Oilfield Phase I (2010 Year 12 Month, 2300kW×2 Fans) and Phase III (2014 Year 3 Month, 2240kW Pumps). Injection water pumps require stable pressure and continuous operation. The high-voltage variable frequency drive adjusts pump speed to match water injection demand, reducing backflow and throttling losses. This platform supports soft starting, multi-pump coordinated control, and constant-pressure network management for pump loads, minimizing water hammer effects and mechanical wear. Project Value: Continuous adoption across multiple oilfield phases; stable water injection system pressure; reduced mechanical wear on pump units.
RESULTS
Transformation Results
KEY METRICS
3700kW
1Tai
Injection Pump
2012-07
Middle East
Variable frequency drive operation ensures stable performance for water injection pumps, reduces pipeline pressure fluctuations, and supports long-term continuous operation of the oilfield water injection system.
Data Scope and Validation Source: The above metrics are derived from on-site measurements under identical operating conditions before and after the retrofit (comparing energy meter readings with equipment operation logs). The statistical period covers 30 consecutive days of full operation post-retrofit. Motor energy efficiency ratings follow GB 18613-2020 and IEC 60034-30-1, while product efficiency values are cited from the manufacturer's factory test reports. Actual results may vary based on load rate, annual operating hours, and specific operating conditions.
STRUCTURED LINKS
Related Products & Industries
Related ProductsCo2Item

Wolong WD5100 Series General-Purpose High-Voltage Variable Frequency Drive
Series-connected multi-level AC-DC-AC high-to-high configuration. 6kV series capacity: 250~9000 kVA; 10kV series: 250~16000 kVA. Input power factor ≥0.95, input current THD ≤4%. Maximum speed ratio 200:1 (FVC). Compatible with asynchronous motors, electrically excited synchronous machines, and permanent magnet synchronous machines. Widely used for energy saving in fans and pumps, as well as process drives, across oil & gas, power, chemical, metallurgy, building materials, and municipal sectors.
View Product Details
Wolong WD5180 Series High-Performance Compact High-Voltage Variable Frequency Drive
1 kV, capacity 280~250 kVA. Shares the same control system as WD5100. Features a fully sealed power unit design for superior environmental adaptability. Overall dimensions are approximately 45% smaller than standard models. Core components like film capacitors offer significantly extended lifespans. Ideal for energy-saving applications in fans and pumps across metallurgy, HVAC, chemical processing, non-ferrous metals, building materials, coal mining, municipal services, power generation, and paper manufacturing sectors.
View Product DetailsRELATED
Products and Solutions in this Project

Petrochemical Measurement & Control
Measurement and control solutions for the petrochemical and chemical industries
Comprehensive measurement and control solutions for the petrochemical and chemical industries, covering explosion-proof selection, pressure, temperature, flow, level, wastewater treatment, and engineering services. Designed to meet ATEX/IECEx compliance and demanding operating conditions.

Pharma & Biotech Measurement Control
Measurement and Control Solutions for the Pharmaceutical and Biotechnology Industries
Measurement and control solutions for the pharmaceutical and biotechnology industries, featuring JUMO hygienic temperature sensors, pressure and differential pressure transmitters, conductivity electrodes and water analysis transmitters, multi-channel process controllers, and paperless recorders. These solutions cover seven key process stages: pharmaceutical water systems, sterilization and disinfection of pharmaceutical products, biopharmaceutical fermentation and production, drying, granulation and coating of fine additives, cleanrooms, gloveboxes, and CIP/SIP cleaning. They enable precise measurement of temperature, pressure, level, and conductivity, along with tamper-proof process data logging and compliant documentation management.
SOLUTIONS
Recommended related solutions

Motor replacement solutions
Address challenges such as aging equipment, motor maintenance needs, and high procurement costs. Leveraging motor parameters, mechanical dimensions, and actual operating conditions, we provide 1 compatible industrial motor replacement solutions for 1, requiring no structural modifications to your equipment.

Permanent Magnet/Synchronous Reluctance Motor Energy Efficiency Retrofit
Replace traditional induction motors with permanent magnet synchronous motors (PMSM) or permanent magnet reluctance motors (PMRM). Optimize motor-load matching based on operating conditions to reduce energy consumption and improve operational stability.

Industrial Energy Saving Solutions Consultation
Factory-wide motor system energy-saving diagnostics and retrofit planning, delivering phased implementation roadmaps and ROI projections.
More Cases
View All
Panpu EC Permanent Magnet Fan Case | Cleanroom Operator | Energy-Saving Retrofit of Cleanroom Fan Clusters with On-Demand Speed Control
Replace traditional AC fan clusters with EC permanent magnet fans, and use differential pressure sensing to enable on-demand speed control for air supply, reducing energy consumption and noise in the cleanroom's ventilation system.

Panpu Permanent Magnet Direct Drive Motor Case: Kiri Chemical Rubber Tire Factory – Whole-Line Drive System Energy Efficiency Retrofit for Tire Production Line
Optimize the motor drive system across the entire tire production line, coordinate multi-device control to reduce overall energy consumption, and adapt to wheel control and molding processes. Help factories achieve energy savings, carbon reduction, and improved production efficiency.

28 0KW Permanent Magnet Motor + VFD Case Study | SCM Chemical Fiber | Large-Scale Process Equipment Retrofit for Energy Efficiency
Equipped with a 280kW permanent magnet motor and dedicated variable frequency drive (VFD), this integrated solution optimizes load performance, reduces energy consumption, and enhances operational stability. It delivers complete case study support to help large-scale process equipment achieve cost reduction and efficiency gains.
Looking for a motor and energy-saving solution tailored to your operating conditions?
Submit request. Our technical engineer will contact you within 1 business days.