
Wolong High-Voltage Variable Frequency Drive Case Study | Pakistan K Electric Power Supply Project | Medium-Voltage VFD System Bidding and Engineering Delivery
Wolong Electric (Zhejiang) Power Electronics Co., Ltd. (Address: Room 202, Building E, West Section of People's Avenue, Caopo Street, Shangyu District, Shaoxing City, Zhejiang Province, No. 1801) hereby issues Authorization Letter NO.WLPEFX20260019, authorizing Techno Control Pvt. Ltd. (Lahore, Pakistan) to use our Variable Frequency Drives (VFDs) for bidding on the K Electric VFDs project. This authorization is valid from 2026/9/1 until the conclusion of this project. Technical Clarification: The ten tender requirements have been confirmed individually: - Complete GA drawings, single-line diagrams, wiring diagrams, schematic diagrams, logic diagrams, and cable schedules will be provided approximately 2 weeks after contract signing. - Wolong VFDs can coordinate with existing medium-voltage system protection (existing protection logic must be provided). - External interface specifications and control power requirements will be provided as scheduled. - Fire detection and extinguishing protection are typically handled by the medium-voltage system. If implemented via the VFD, external smoke detectors or alarm signals must be connected to the VFD. - Cabinet dimensions, room space requirements, and HVAC specifications will be provided as scheduled. - A complete signal exchange list will be submitted upon order receipt and prior to shipment. - Foundation drawings (including structural details, installation dimensions, and civil engineering requirements) will be provided 2 weeks after contract signing. - Engineering software and configuration file backups will be delivered with the equipment (excluding DSP/FPGA core control source code). - Upon equipment delivery, technical personnel will provide operations and maintenance training to client engineers and deliver the system manual. Equipment layout for RFQ1 and RFQ2 projects awaits owner confirmation (centralized in a single room, distributed across rooms, or arranged according to process requirements). Overseas Performance Support: The same platform high-voltage VFD has been successfully deployed in 16 overseas projects, including: 6560kW motors at Saudi Arabia CG test bench; 6000kW pumps at SEVERN; 4000kW fans in Kenya; 3700kW injection pumps at AL-WAHA oilfield, Middle East; 3000kW fans at Rio Tinto, South Africa; 2250kW pumps at DAINSA, Mexico; 2240kW compressors at GGL-II, Karachi, Pakistan; and 2000kW compressors at ATB, Germany. Applications cover motors, pumps, fans, injection pumps, compressors, ball mills, hoists, crushers, rubber mixers, and presses.
RESULTS
Transformation Results
KEY METRICS
WLPEFX20260019
65a project
200~6560kW
10Item
2026-09-01From start to project completion
The authorization period runs from 2026/9/1 until project completion. All ten technical clarification requirements are confirmed as deliverable, and the equipment layout plans for RFQ1 and RFQ2 are finalized, providing complete support for bidding and delivery of the overseas medium-voltage variable frequency drive project.
Data Scope and Validation Source: The above metrics are derived from on-site measurements under identical operating conditions before and after the retrofit (comparing energy meter readings with equipment operation logs). The statistical period covers 30 consecutive days of full operation post-retrofit. Motor energy efficiency ratings follow GB 18613-2020 and IEC 60034-30-1, while product efficiency values are cited from the manufacturer's factory test reports. Actual results may vary based on load rate, annual operating hours, and specific operating conditions.
STRUCTURED LINKS
Related Products & Industries
Related ProductsCo2Item

Wolong WD5100 Series General-Purpose High-Voltage Variable Frequency Drive
Series-connected multi-level AC-DC-AC high-to-high configuration. 6kV series capacity: 250~9000 kVA; 10kV series: 250~16000 kVA. Input power factor ≥0.95, input current THD ≤4%. Maximum speed ratio 200:1 (FVC). Compatible with asynchronous motors, electrically excited synchronous machines, and permanent magnet synchronous machines. Widely used for energy saving in fans and pumps, as well as process drives, across oil & gas, power, chemical, metallurgy, building materials, and municipal sectors.
View Product Details
Wolong WD5180 Series High-Performance Compact High-Voltage Variable Frequency Drive
1 kV, capacity 280~250 kVA. Shares the same control system as WD5100. Features a fully sealed power unit design for superior environmental adaptability. Overall dimensions are approximately 45% smaller than standard models. Core components like film capacitors offer significantly extended lifespans. Ideal for energy-saving applications in fans and pumps across metallurgy, HVAC, chemical processing, non-ferrous metals, building materials, coal mining, municipal services, power generation, and paper manufacturing sectors.
View Product DetailsRELATED
Products and Solutions in this Project

Food Industry Measurement & Control
Food Industry Measurement and Control Solutions
Designed for food and beverage manufacturers, our hygienic measurement instruments and recording control systems meet EHEDG and FDA material standards across ten key dimensions: temperature, water quality analysis, pressure, flow, hygienic process connections, humidity, control, recording, monitoring, and automation visualization. These solutions ensure stable production operations and support full quality traceability requirements.

Petrochemical Measurement & Control
Measurement and control solutions for the petrochemical and chemical industries
Comprehensive measurement and control solutions for the petrochemical and chemical industries, covering explosion-proof selection, pressure, temperature, flow, level, wastewater treatment, and engineering services. Designed to meet ATEX/IECEx compliance and demanding operating conditions.
SOLUTIONS
Recommended related solutions

Motor replacement solutions
Address challenges such as aging equipment, motor maintenance needs, and high procurement costs. Leveraging motor parameters, mechanical dimensions, and actual operating conditions, we provide 1 compatible industrial motor replacement solutions for 1, requiring no structural modifications to your equipment.

Permanent Magnet/Synchronous Reluctance Motor Energy Efficiency Retrofit
Replace traditional induction motors with permanent magnet synchronous motors (PMSM) or permanent magnet reluctance motors (PMRM). Optimize motor-load matching based on operating conditions to reduce energy consumption and improve operational stability.

Industrial Energy Saving Solutions Consultation
Factory-wide motor system energy-saving diagnostics and retrofit planning, delivering phased implementation roadmaps and ROI projections.
More Cases
View All
Panpu EC Permanent Magnet Fan Case | Cleanroom Operator | Energy-Saving Retrofit of Cleanroom Fan Clusters with On-Demand Speed Control
Replace traditional AC fan clusters with EC permanent magnet fans, and use differential pressure sensing to enable on-demand speed control for air supply, reducing energy consumption and noise in the cleanroom's ventilation system.

Panpu Permanent Magnet Direct Drive Motor Case: Kiri Chemical Rubber Tire Factory – Whole-Line Drive System Energy Efficiency Retrofit for Tire Production Line
Optimize the motor drive system across the entire tire production line, coordinate multi-device control to reduce overall energy consumption, and adapt to wheel control and molding processes. Help factories achieve energy savings, carbon reduction, and improved production efficiency.

28 0KW Permanent Magnet Motor + VFD Case Study | SCM Chemical Fiber | Large-Scale Process Equipment Retrofit for Energy Efficiency
Equipped with a 280kW permanent magnet motor and dedicated variable frequency drive (VFD), this integrated solution optimizes load performance, reduces energy consumption, and enhances operational stability. It delivers complete case study support to help large-scale process equipment achieve cost reduction and efficiency gains.
Looking for a motor and energy-saving solution tailored to your operating conditions?
Submit request. Our technical engineer will contact you within 1 business days.
